Infusion Pump Flight 750 for IV Therapy
Infusion Pump Flight 750 for IV Therapy
Infusion Pump Flight 750 for IV Therapy
Infusion Pump Flight 750 for IV Therapy
Infusion Pump Flight 750 for IV Therapy
Infusion Pump Flight 750 for IV Therapy

Infusion Pump Flight 750 for IV Therapy

Sale priceRs. 17,999 Regular priceRs. 29,440
Save 39%

Tax included. Shipping calculated at checkout

Quantity:

Contact Us

Meddey Technologies Pvt. Ltd.

C-75, First Floor, DDA Sheds Industrial Area,Phase 1,
Okhla, New Delhi-110020 INDIA
GST No:- 07AAKCM6565B2ZD

Medansh Customer Care:

Phone / WhatsApp :85 86 012345

Email: cs@meddey.com

Infusion Pump Flight 750 for Accurate IV Fluid Delivery

The infusion pump Flight 750 is designed for precise fluid administration in hospitals, ICUs, emergency rooms, operation theatres, and clinical care units. It helps healthcare professionals deliver IV fluids with controlled flow, accurate dosing support, and dependable alarm-based monitoring.

Available at Meddey, the Infusion Pump Flight 750 supports controlled infusion for different medical requirements. Since IV therapy demands accuracy and safety, this volumetric infusion pump is suitable for clinical environments where staff need stable performance and clear operating information.

Precision Infusion Control

The SP750 volumetric infusion pump supports a flow rate range of 1 ml/h to 699 ml/h. In addition, it offers preset volume control from 1 ml to 9999 ml, which helps clinicians plan infusion delivery according to patient care requirements.

Moreover, the device displays important working information such as infusion rate, total volume, infused volume, and residual time. As a result, trained medical staff can monitor infusion status more effectively during patient care.

Safety-Oriented Clinical Design

This infusion pump includes multiple alarm functions such as door open, occlusion, air bubbles, motor failure, communication failure, near end, KVO state, low power, and no power. Therefore, it supports better procedural awareness in busy clinical settings.

It also includes Anti-Bolus System support and automatic flow shut-off during alarm conditions, except selected conditions such as KVO and low battery. The pump should be operated only by trained healthcare professionals following hospital protocols.

Key Features

  • Accurate Infusion Delivery: Supports controlled IV fluid administration with ±5% accuracy after IV set calibration.
  • Wide Flow Rate Range: Allows infusion from 1 ml/h to 699 ml/h for different clinical requirements.
  • Anti-Bolus System: Helps reduce the risk of sudden high-dose delivery during controlled use.
  • Alarm Safety Support: Includes alarms for occlusion, air bubbles, door open, motor failure, low power, and more.
  • KVO Function: Keep Vein Open rate of 1–5 ml/h supports professional infusion workflow.
  • Clear Display Information: Shows infusion rate, total volume, infused volume, and residual time.
  • Compact Aluminium Construction: Space-saving design supports easy mounting in clinical areas.
  • USB Port: Supports software updates by technical personnel.
  • Multi-Language Support: Offers Chinese and English language options.

Technical Specifications

Specification Details
Product Name Infusion Pump Flight 750
Model / Type SP750 Volumetric Infusion Pump
Flow Rate 1 ml/h – 699 ml/h
Bolus Rate 699 ml/h
Preset Volume Range 1 ml – 9999 ml
Accuracy ±5% with IV Set Calibration
KVO Rate 1 – 5 ml/h
Display Information Infusion Rate, Total Volume, Infused Volume, Residual Time
Alarm Functions Door Open, Occlusion, Air Bubbles, Motor Failure, Communication Failure, Near End, KVO State, Low Power, No Power
Occlusion Pressure 100 kPa – 300 kPa
Safety Classification Class I, Type BF; DC Input Part Class II, Type BF
Water Resistance IPX1
Working Mode Continuous Operation
Power Supply AC 100–240V, 50/60Hz or DC 12V
Battery Rechargeable Li-Ion 7.4V / 3700 mAh
Box Contents Versatile Bracket, Power Cord, User Manual
Warranty 1 Year
Country of Origin China
Manufacturer / Importer / Marketed By Meddey Technologies Pvt. Ltd., C-75, First Floor, DDA Sheds, Industrial Area, Phase 1, Okhla, New Delhi - 110020. Phone: +91 8586-012345

Benefits of Infusion Pump Flight 750

The Infusion Pump Flight 750 supports accurate IV fluid administration for professional healthcare settings. It helps clinical teams manage infusion rate, infused volume, and residual time with better visibility.

In addition, its alarm system supports safer workflow by alerting users to common infusion-related issues. The compact construction and mounting-friendly design also make it practical for hospitals, ICU units, patient rooms, and emergency departments.

This infusion pump is intended for trained medical users only. It should always be used according to hospital policy, manufacturer instructions, and professional clinical judgment.

Common Applications

  • IV fluid administration in hospitals
  • ICU and emergency care infusion support
  • Operation theatre fluid delivery support
  • Patient room and ward-based infusion management
  • Controlled infusion for clinical treatment protocols
  • Medical facilities requiring accurate volumetric infusion control

Why Choose Meddey?

Meddey offers professional medical equipment, hospital supplies, and clinical devices for healthcare institutions across India. This infusion pump is suitable for hospitals and clinical buyers who need accurate delivery, alarm safety, KVO support, and reliable infusion workflow.

Furthermore, Meddey supports convenient online ordering, clinical product sourcing, and procurement assistance for medical professionals, hospitals, and healthcare facilities.

FAQ Section

What is the Infusion Pump Flight 750 used for?

The Infusion Pump Flight 750 is used for controlled IV fluid administration in professional healthcare settings. It helps clinicians deliver fluids at a selected flow rate and monitor infusion volume during patient care. The pump is suitable for hospitals, ICUs, emergency rooms, operation theatres, wards, and clinical treatment areas. Since infusion therapy involves patient safety, the device should only be used by trained healthcare professionals.

What is the flow rate range of this infusion pump?

The pump supports a flow rate range from 1 ml/h to 699 ml/h. This wide range helps clinicians choose the required infusion rate according to patient condition, medication protocol, and treatment plan. However, flow rate selection must always follow clinical judgment, prescription requirements, and hospital procedures.

Does the pump include alarm functions?

Yes, this infusion pump includes multiple alarm functions, including door open, occlusion, air bubbles, motor failure, communication failure, near end, KVO state, low power, and no power. These alarms help clinical users identify issues during infusion workflow. However, alarms do not replace continuous professional monitoring.

What is the KVO function?

KVO means Keep Vein Open. The pump offers a KVO rate from 1 to 5 ml/h. This function helps maintain minimal flow when clinically required. The KVO setting should be used only according to hospital protocol and professional instructions.

What comes inside the box?

The box includes a versatile bracket, power cord, and user manual. The bracket supports convenient mounting, while the power cord supports device operation through AC supply. Users should read the manual carefully and ensure trained staff understand setup, alarms, calibration, and safety checks before use.

Who should operate this device?

This device should be operated only by trained nurses, doctors, biomedical staff, or authorized clinical personnel. Infusion pumps require correct setup, IV set calibration, pressure monitoring, alarm response, and patient observation. It is not intended for personal or unsupervised use.

Quick Tips for Using Infusion Pump

Before Use

  • Use Trained Staff Only: The infusion pump should be operated only by trained healthcare professionals who understand IV infusion setup, flow rate selection, alarms, and patient safety.
  • Check the Device: Inspect the pump body, display, power cord, bracket, battery status, and IV set connection before use. Do not use the device if any part appears damaged.
  • Confirm IV Set Compatibility: Use a compatible IV set and perform calibration as required. Proper calibration supports the stated accuracy and improves delivery reliability.
  • Verify Prescription: Confirm infusion rate, total volume, medication details, patient identity, and clinical order before starting the infusion.

During Infusion

  • Monitor Display Values: Check the infusion rate, total volume, infused volume, and residual time regularly. This helps staff follow the planned infusion workflow.
  • Respond to Alarms Quickly: If the pump alerts for occlusion, air bubbles, low power, door open, or other conditions, respond according to hospital protocol.
  • Keep the Line Safe: Ensure the IV line is not kinked, compressed, pulled, or positioned in a way that may affect flow or trigger alarms.
  • Use KVO Appropriately: KVO should be used only when clinically required and according to professional instructions.
  • Avoid Unattended Use: Even with alarm functions, patient monitoring remains important. Staff should observe patient response, IV site condition, and device operation.

After Use and Maintenance

  • Stop and Disconnect Properly: After completing infusion, stop the pump according to instructions and follow clinical procedure for IV line management.
  • Clean According to Protocol: Clean the device exterior as per hospital infection-control policy. Avoid excess liquid exposure because the water resistance rating is IPX1.
  • Charge the Battery: Keep the rechargeable Li-Ion battery charged so the pump remains ready for clinical use.
  • Store Safely: Store the pump, bracket, power cord, and manual in a clean and dry location when not in use.
  • Schedule Biomedical Checks: Arrange routine inspection, servicing, and calibration checks through authorized technical or biomedical personnel.
  • Train Users Regularly: Provide periodic training for nurses and clinical users on alarms, calibration, safe setup, ABS, KVO, and troubleshooting.