
SP08 Syringe Infusion Pump for Hospital & ICU Use
Choose options
The SP08 syringe infusion pump is designed for controlled syringe-based fluid delivery in hospitals, ICUs, clinics and other healthcare settings.
In simple terms, a syringe pump moves the plunger of a loaded syringe at a programmed rate. Therefore, trained healthcare professionals can set the device according to the prescribed infusion plan.
In addition, the SP08 supports several syringe sizes, multiple operating modes and flow settings up to 1500 mL/h. However, correct setup, compatible syringes and trained operation remain important for safe use.
SP08 Syringe Infusion Pump – Key Features
Hospital Syringe Pump for Controlled Infusion
A hospital syringe pump helps deliver fluid from a syringe at a programmed rate. Therefore, it can support clinical situations where staff need controlled syringe-based delivery.
First, the healthcare professional selects a compatible syringe. Next, the required settings are entered according to the treatment plan.
However, the pump does not decide the correct medicine, dose or infusion rate by itself. Instead, qualified healthcare staff should select and verify those settings.
SP08 Syringe Infusion Pump Operating Modes
The SP08 syringe infusion pump provides three listed operating modes.
- Speed mode: the user sets the required infusion rate.
- Speed + Time mode: the rate is used together with a programmed time.
- Speed + Volume mode: the rate is used together with a target volume.
Therefore, trained staff can select a mode that suits the prescribed infusion setup.
Medical Syringe Infusion Pump with Multiple Syringe Sizes
This medical syringe infusion pump supports 5 mL, 10 mL, 20 mL, 30 mL, 50 mL and 60 mL syringe sizes according to the current product specification.
However, syringe size alone does not confirm that every syringe brand or model will work correctly. Therefore, always follow the supplied instructions and use compatible syringes.
In addition, healthcare staff should verify the syringe and programmed settings before starting an infusion.
SP08 Syringe Pump Flow Rate Settings
| 5 mL Syringe | 0.1–150 mL/h |
|---|---|
| 10 mL Syringe | 0.1–300 mL/h |
| 20 mL Syringe | 0.1–600 mL/h |
| 30 mL Syringe | 0.1–900 mL/h |
| 50 mL Syringe | 0.1–1500 mL/h |
For lower rates from 0.1 to 100 mL/h, the listed minimum adjustment step is 0.1 mL/h. Meanwhile, from 101 to 1500 mL/h, the listed adjustment step is 1 mL/h.
Although a 60 mL syringe is listed as compatible, the current specification does not provide a separate 60 mL flow-rate range. Therefore, we have not added an unverified value.
SP08 Syringe Infusion Pump Technical Specifications
| Model | SP08 |
|---|---|
| Product Type | Syringe Infusion Pump |
| Display Size | 3.8 Inches |
| Weight | 1.5 kg |
| Listed Accuracy | No More Than ±2% |
| Battery Working Time | Not Less Than 4 Hours |
| KVO Rate | 2.5 mL/h |
| Dimensions | 248 × 151.5 × 97 mm |
| Time Setting Range | 1 Minute to 99:59 Minutes |
| Supported Syringe Sizes | 5, 10, 20, 30, 50 and 60 mL |
| Maximum Listed Flow Rate | 1500 mL/h |
| Operating Temperature | 5–40°C |
| Relative Humidity | Less Than 80% |
What Does KVO Mean on a Syringe Pump?
KVO means Keep Vein Open. In simple words, it refers to a low flow setting used in certain infusion setups to help maintain the IV line according to the clinical plan.
The SP08 lists a KVO rate of 2.5 mL/h. However, healthcare professionals should follow the prescribed treatment and device instructions rather than treating the KVO value as a universal setting.
Syringe Pump for ICU and Clinical Use
A syringe pump for ICU and other clinical areas needs careful setup because small changes in programmed delivery may matter during treatment.
Therefore, trained staff should check the prescribed rate, syringe compatibility and device settings before use. In addition, they should follow their hospital or clinic procedures for infusion-pump operation.
The FDA also notes that infusion pumps are generally programmed by trained users and that pump problems can potentially cause over-infusion, under-infusion or treatment delays. Therefore, correct training and checking remain important.
SP08 Syringe Pump – Important Safety Guidance
- First, use the pump according to the supplied instructions and clinical protocol.
- Next, confirm that the selected syringe is compatible with the pump.
- In addition, verify the programmed rate, volume and time before starting the infusion.
- Also, make sure the syringe is fitted correctly before operation.
- Meanwhile, monitor the infusion and the patient according to the healthcare facility's procedure.
- However, do not change a prescribed medicine or infusion rate without appropriate clinical authorization.
- Finally, stop using the pump and follow the appropriate clinical procedure if the device appears damaged or does not operate as expected.
SP08 Syringe Infusion Pump FAQs
What Is the SP08 Syringe Infusion Pump Used For?
It is designed for controlled syringe-based fluid delivery in suitable healthcare settings. Therefore, trained staff should program it according to the prescribed infusion plan.
Which Syringe Sizes Does the SP08 Syringe Pump Support?
The listed compatible sizes are 5, 10, 20, 30, 50 and 60 mL.
What Is the Maximum Flow Rate?
The maximum listed flow rate is 1500 mL/h with the applicable syringe and programmed setting.
What Is the Listed Accuracy of the SP08?
The current product specification lists infusion accuracy as no more than ±2%.
How Long Does the Battery Work?
The current Meddey specification lists a battery working time of not less than four hours.
What Does KVO Mean?
KVO means Keep Vein Open. The SP08 lists a KVO rate of 2.5 mL/h.
What Operating Modes Are Available?
The listed modes are speed, speed + time and speed + volume.
Can the SP08 Be Used at Home?
An infusion pump may sometimes form part of home healthcare, but proper training and clinical instructions are important. Therefore, household users or caregivers should not independently select medication doses or infusion settings.
Can Any Syringe Brand Be Used?
Do not assume that every syringe brand is compatible. Instead, use the correct syringe size and follow the pump manufacturer's compatibility and setup instructions.
Need Help with the SP08 Syringe Infusion Pump?
Contact Meddey for current availability, ordering information and product-specific guidance.
Prepaid or Partial COD options are available.
Meddey Technologies Pvt. Ltd.
C-75, First Floor, DDA Sheds
Industrial Area, Phase 1
Okhla, New Delhi – 110020
India
Call / WhatsApp: +91 8586-012345
